Water and CO2 can interfere with the CO analyser
performance. Therefore, a CO2 span gas having a concentration
of 80% to 100% of full scale of the maximum operating range used during
testing shall be bubbled through water at room temperature and the
analyser response recorded. The analyser response must not be more
than 1% of full scale for ranges equal to or above 300 ppm or more
than 3 ppm for ranges below 300 ppm.