4.9.1 In addition to complying with the requirements
of section 4.8, a flre-protected lifeboat
when waterborne shall be capable of protecting the number of persons
it is permitted to accommodate when subjected to a continuous oil
fire that envelopes the lifeboat for a period of not less than 8 min.