4.3.1 The construction, erection and stiffening
of the test specimen should be typical of the use in practice.
4.3.2 For vertical division (bulkheads), the minimum
overall dimensions for the exposed part of the test specimen are 2,440
mm width and 2,500 mm height, or full height if the height is smaller.
4.3.3 For horizontal divisions (decks), the minimum
overall dimensions for the exposed part of the test specimen are 2,440
mm width and 3,040 mm length (span), or full length if the length
is smaller.