This document has been consolidated into SOLAS
CHAPTER II-1
CONSTRUCTION – STRUCTURE, SUBDIVISION AND STABILITY, MACHINERY AND ELECTRICAL
INSTALLATIONS
Part A - General
Regulation 3-12 – Protection against noise
1 The existing paragraph 2.1 is amended to read as follows:
CHAPTER II-2
CONSTRUCTION – FIRE PROTECTION, FIRE DETECTION AND FIRE EXTINCTION
Part A - General
Regulation 1 – Application
2 The following new paragraph is added after existing paragraph 2.8:
-
"2.9 Regulation 10.5.1.2.2, as amended by resolution MSC.409(97), applies to ships constructed before 1
January 2020, including those constructed before 1 July 2012."
Part C - Suppression of Fire
Regulation 10 – Firefighting
3 In paragraph 5.1.2.2, the last sentence is replaced with the following:
-
"In the case of domestic boilers of less than 175 kW, or boilers
protected by fixed water-based local application fire-extinguishing systems
as required by paragraph 5.6, an approved foam-type extinguisher of at least
135 / capacity is not required."
CHAPTER XI-1
SPECIAL MEASURES TO ENHANCE MARITIME SAFETY
4 The following new regulation 2-1 is inserted after existing regulation 2:
-
"Regulation 2-1 – Harmonization of survey periods of cargo ships not
subject to the ESP Code
-
For cargo ships not subject to enhanced surveys under regulation XI-1/2,
notwithstanding any other provisions, the intermediate and renewal surveys
included in regulation I/10 may be carried out and completed over the
corresponding periods as specified in the 2011
ESP Code, as may be amended, and the guidelines developed by the
Organizationfootnote, as appropriate.