Part B - Requirements for Passenger Craft
Clasification Society 2024 - Version 9.40
Statutory Documents - IMO Publications and Documents - International Codes - HSC Code - International Code of Safety for High Speed Craft, 1994 – Resolution MSC.36(63) - Annex - International Code of Safety for High Speed Craft, 1994 - Chapter 7 - Fire Safety - Part B - Requirements for Passenger Craft

Part B - Requirements for Passenger Craft

7.11 Arrangement

  7.11.1 For category B craft, the public spaces should be divided into zones according to the following:

  • .1 The craft should be divided into at least two zones. The mean length of each zone should not exceed 40 m.

  • .2 For the occupants of each zone there should be an alternative safe area to which it is possible to escape in case of fire. The alternative safe area should be separated from other passenger zones by smoke-tight divisions of non-combustible materials or fire-restricting materials extending from deck to deck. The alternative safe area can be another passenger zone provided the additional number of passengers may be accommodated in an emergency.

  • .3 The alternative safe area should, as far as practicable, be located adjacent to the passenger zone it is intended to serve. There should be at least two exits from each passenger zone, located as far away from each other as possible, leading to the alternative safe area. Escape routes should be provided to enable all passengers and crew to be safely evacuated from the alternative safe area.

  7.11.2 Category A craft need not be divided into zones.

  7.11.3 Control stations, life-saving appliance stowage positions, escape routes and places of embarkation into survival craft should not, as far as practicable, be located adjacent to any major or moderate fire hazard areas.

7.12 Ventilation

 The ventilation fans of each zone in the accommodation spaces should also be capable of being independently controlled from a continuously manned control station

7.13 Fixed sprinkler System

  7.13.1 Public spaces and service spaces, storage rooms other than those containing flammable liquids, and similar spaces should be protected by a fixed sprinkler system meeting a standard developed by the Organization. Manually operated sprinkler systems should be divided into sections of appropriate size, and the valves for each section, start of sprinkler pump(s) and alarms should be operable from two spaces separated as widely as possible, one of which should be a continuously manned control station. In category B craft, no section of the system should serve more than one of the zones required in 7.11.

  7.13.2 Plans of the system should be displayed at each operating station. Suitable arrangements should be made for the drainage of water discharged when the system is activated.


Copyright 2022 Clasifications Register Group Limited, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasifications Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasifications Register'. Clasifications Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasifications Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.