3 Auxiliary systems
3.1 General requirements
3.1.1 Atmospheric diving suits shall, where appropriate:
- contain valves, gauges and such other equipment as are necessary to control
the propulsion and auxiliary systems, including any fuel supply and exhaust
systems;
- contain such valves, gauges and other equipment as are necessary to control
the depth, attitude, and rate of descent and ascent without inducing
resonant or unstable motions;
- The ADS is to be provided with an emergency surfacing system, be fitted with
jettisonable weights or other means, suitably protected against inadvertent
operation, to achieve positive buoyancy in an envisaged emergency. This
system is to permit the ADS to ascend to the surface when disconnected from
its tether/umbilical. The system is to provide positive buoyancy sufficient
to ascend to the surface from any operational depth. Emergency surfacing
system activation is to require at least two positive manual actions for
operation and is to be independent of electrical power. Emergency ascent
calculations (addressing the net positive buoyancy provided and the
resultant ascent rate) are to be submitted for review and approval. The
emergency surfacing system is to operate properly under all anticipated
conditions of heel and trim;
- be fitted with valves or other fittings to enable manipulators, grasping or
anchoring devices and jettisonable equipment to be released in a planned or
envisaged emergency;
- the ADS is to be configured such that it will automatically and naturally
assume a normally upright or comfortable position, when not influenced by
the pilot’s body motion or thrusters;
- the ADS stability analysis, test procedures and test results are to be
submitted for approval;
- be fitted with an umbilical capable of maintaining services and of
sufficient strength for its intended service;
- be equipped with an internal release, suitably protected against inadvertent
operation, for severing or releasing the umbilical cable.
|
|
Copyright 2022 Clasifications Register Group Limited, International Maritime Organization, International Labour Organization or Maritime
and Coastguard Agency. All rights reserved. Clasifications Register Group Limited, its affiliates and subsidiaries and their respective
officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasifications Register'. Clasifications
Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance
on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant
Clasifications Register entity for the provision of this information or advice and in that case any responsibility or liability is
exclusively on the terms and conditions set out in that contract.
|
 |
|