Refer to the following publication IEC 60529-(2003)-
(a) electrical motors, associated circuits and control components;
protected to IPX 7 standard;
(b) door position indicators and associated circuit components; protected
to IPX 8 standard; and
(c) door movement warning signals; protected to IPX 6 standard.
Other arrangements for the enclosures of electrical
components may be fitted provided the Administration is satisfied that
an equivalent protection is achieved. The water pressure IPX 8 shall be
based on the pressure that may occur at the location of the component
during flooding for a period of 36 hours.