4.1 Unless authorized under special arrangements
by the regulatory authority:
-
.1 the radiation doses levels likely to be encountered
from any package, “overpack”, freight container or tank
in a port area should not exceed 2 mSv/h at the external surface or
0.1 mSv/h at 2 metres from the surface of any conveyance used in routine
transport; and
-
.2 the total number of packages, overpacks, freight
containers or tanks aboard a single conveyance or a single stack in
a port area should be so limited that the total sum of the transport
indices does not exceed 50.
4.2 The total sum of the transport indices of
any individual group of packages, overpacks, freight containers or
tanks stowed in a port area should not exceed 100. An intervening
space of at least 6 m should be left between groups. A number of stacks
may be included in the same group.
4.3 Stowage of packages, overpacks, freight containers
and tanks aboard ships shall be in accordance with the requirements
for class 7 set out in chapter 7.1 of the IMDG Code.
4.4 Segregation provisions for packages, overpacks,
freight containers and tanks aboard ships shall be in accordance with
the requirements of class 7 set out in chapter 7.2 of the IMDG Code.