Clasification Society Rulefinder 2020 - Version 9.33 - Fix
Statutory Documents - MCA Publications - LY3 - The Large Commercial Yacht Code - 14A Structural Fire Protection - Vessels of Less than 500GT - 14A.1 General

14A.1 General

  14A.1.1 Terms used in this section should have the same meaning as defined in SOLAS.

Table 14A.1.1 is a guide to the major requirements of this Section. The Table is intended as a quick reference to the requirements and is not to be used in isolation when designing the fire safety arrangements.

Passive fire protection (see 14A.2). Category ‘A’ machinery spaces:
‘A-30’,
(B-15 for short range yachts);

Galleys: B-15 (for yachts not being Short Range Yachts)’.
Means of escape (see 14A.3).  
  • Category 'A' machinery spaces.
Two (2).
  • Accommodation and other spaces.
Two (2).
Fixed fire detection system (see 14A.7).
  • Fitted in machinery spaces.
  • Fitted in service spaces, control stations and accommodation spaces.
Automatic sprinkler system or equivalent Fitted in yachts that do not meet restrictions on combustible materials (14A.2.3.6 & 14A.2.3.8).

Copyright 2020 Clasification Society, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasification Society, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasification Society'. Clasification Society Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasification Society entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.