Regulation 4 - Bulkheads within the accommodation and service spaces
Clasification Society 2024 - Version 9.40
Statutory Documents - IMO Publications and Documents - International Conventions - SFV - International Convention for the Safety of Fishing Vessels (The Torremolinos Convention)Regulations for the Construction and Equipment of Fishing Vessels - Chapter V - Fire Protection, Fire Detection, Fire Extinction and Fire Fighting - (See also regulation IV/19) - Part B - Fire Safety Measures in Vessels of 60 metres in Length and Over - Regulation 4 - Bulkheads within the accommodation and service spaces

Regulation 4 - Bulkheads within the accommodation and service spaces

  (1) Within the accommodation and service spaces, all bulkheads required to be "B" class divisions shall extend from deck to deck and to the shell or other boundaries, unless continuous "B" class ceilings or linings, or both, are fitted on both sides of the bulkheads in which case the bulkhead may terminate at the continuous ceiling or lining.

  (2) Method IF. All bulkheads not required by this or other regulations of this part to be "A" or "B" class divisions shall be at least "C" class divisions.

  (3) Method IIF. There shall be no restriction on the construction of bulkheads not required by this or other regulations of this part to be "A" or "B" class divisions except in individual cases where "C" class bulkheads are required in accordance with table 1 in regulation 7.

  (4) Method IIIF. There shall be no restriction on the construction of bulkheads not required by this or other regulations of this part to be "A" or "B" class divisions. In no case shall the area of any accommodation space or spaces bounded by a continuous "A" or "B" class division exceed 50 m2, except in individual cases where "C" class bulkheads are required in accordance with table 1 in regulation 7. However, the Administration may increase this area for public spaces.

Table 1 Fire integrity of bulkheads separating adjacent spaces

Spaces (1) (2) (3) (4) (5) (6) (7) (8) (9) (10)
Control stations (1) A-0c A-0 A-60 A-0 A-15 A-60 A-15 A-60 A-60 *
Corridors (2)   C B-0 B-0
A-0c
B-0 A-60 A-0 A-0 A-0 *
Accommodation spaces (3)     Ca,b B-0
A-0c
B-0 A-60 A-0 A-0 A-0 *
Stairways (4)       B-0
A-0c
B-0
A-0c
A-60 A-0 A-0 A-0 *
Service spaces of low fire risk (5)         C A-60 A-0 A-0 A-0 *
Machinery spaces of category A (6)           * A-0 A-0 A-60 *
Other machinery spaces (7)             A-0d A-0 A-0 *
Cargo spaces (8)               * A-0 *
Service spaces of high fire risk (9)                 A-0d *
Open decks (10)                   -

Note (see table 2)


Copyright 2022 Clasifications Register Group Limited, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasifications Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasifications Register'. Clasifications Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasifications Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.