The product of time from initial specimen exposure until
arrival of the flame front and the incident flux level at that same
location as measured with a dummy specimen during calibration. The
longest time used in this calculation should correspond to flame arrival
at a station at least 30 mm prior to the position of furthest flame
propagation on the centreline of the specimen.