2.2.1 The design current density to be used for permanent water ballast tanks
                                 should be based on a minimum value of 110 mA/m2 but this may have to be
                                 increased to at least 130 mA/m2 if hot oil is stored on the opposite side
                                 of the bulkhead. For a coating allowance, see
                                 Pt  8, Ch  4,  1.1 Current density 1.1.6. 
                              
                              
                              
                            
                           
                           
                           
                              
                              
                              2.2.2 Uncoated tanks used for the storage of crude oil at ambient temperature
                                 alternating with water ballast are to have a minimum current density of 90
                                 mA/m2; however, this should be increased for higher temperatures.
                                 
                              
                              
                              
                            
                           
                           
                           
                              
                              
                              2.2.3 Unless otherwise agreed the resistivity of the water in ballast tanks
                                 should be assumed to be 25 ohm.cm.