8.1 An OMM should be prepared to cover each EGC unit installed in conjunction
with fuel oil combustion equipment, which should be identified, for which compliance is
to be demonstrated.
8.2 The OMM should, as a minimum, include:
- .1 the sensors to be used in evaluating EGC system performance and washwater
monitoring, their service, maintenance and calibration requirements;
- .2 the positions from which exhaust emission measurements and washwater
monitoring are to be taken together with details of any necessary ancillary
services such as sample transfer lines and sample treatment units and any
related service or maintenance requirements;
- .3 the analysers to be used, their service, maintenance, and calibration
requirements;
- .4 analyser zero and span check procedures; and
- .5 other information or data relevant to the correct functioning of the
monitoring systems or its use in demonstrating compliance.
8.3 The OMM should specify how the monitoring is to be surveyed.
8.4 The OMM should be approved by the Administration.