Regulation II-2/19.3.2 - Sources of ignition
Clasification Society 2024 - Version 9.40
Statutory Documents - IMO Publications and Documents - Circulars - Maritime Safety Committee - MSC.1/Circular.1203 – Unified Interpretations of SOLAS Chapter II-2 and Fire Test Procedures Referred to in the FTP Code – (26 May 2006) - Annex - Unified Interpretations of SOLAS Chapter II-2 and the Fire Test Procedures Referred to in the FTP Code - Regulation II-2/19.3.2 - Sources of ignition

Regulation II-2/19.3.2 - Sources of ignition

  1 Reference should be made to IEC 60092-506 standard, Special features - Ships carrying specific dangerous goods and materials hazardous only in bulk.

  2 For pipes having open ends (e.g., ventilation and bilge pipes, etc.) in a hazardous area, the pipe itself should be classified as a “hazardous area”. See IEC 60092-506 table B1, item B.

  3 Enclosed spaces (e.g., pipe tunnels, bilge pump-rooms, etc.) containing such pipes with equipment such as flanges, valves, pumps, etc., should be regarded as an extended hazardous area, unless provided with overpressure in accordance with IEC 60092-506 clause 7.


Copyright 2022 Clasifications Register Group Limited, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasifications Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasifications Register'. Clasifications Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasifications Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.