The RO should have the appropriate competence, capability
and capacity to perform the following technical evaluations and/or
calculations pertaining to:
- longitudinal strength;
- local scantlings such as plates and stiffeners;
- structural stress, fatigue and buckling analyses;
- materials, welding and other pertinent methods of material-joining,
for compliance with relevant rules and convention requirements