Section 7.17.3.1.2 Required capacity of water supply for fire-extinguishing
Clasification Society 2024 - Version 9.40
Statutory Documents - IMO Publications and Documents - Circulars - Maritime Safety Committee - MSC/Circular.1102 – Interpretations of the 2000 HSC Code and SOLAS Chapter X – (15 September 2003) - Annex 1 - Interpretations of Provisions of the 2000 HSC Code - Section 7.17.3.1.2 Required capacity of water supply for fire-extinguishing

Section 7.17.3.1.2 Required capacity of water supply for fire-extinguishing

 The total required capacity of the water supply should satisfy SOLAS regulations II-2/19.3.1.2 and II-2/19.3.1.3 (if applicable), simultaneously calculated for the largest designated cargo space. The capacity requirement for SOLAS regulation II-2/19.3.1.2 should be met by the total capacity of the main fire pump(s) not including the capacity of the emergency fire pump, if fitted. If a drencher system is used to satisfy SOLAS regulation II-2/19.3.1.3, then the drencher pump should also be taken into account in this total capacity calculation.


Copyright 2022 Clasifications Register Group Limited, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasifications Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasifications Register'. Clasifications Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasifications Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.