Section 7.7.3.2.7 Warning of release of extinguishing medium to ro-ro spaces and other spaces where personnel can enter
Clasification Society 2024 - Version 9.40
Statutory Documents - IMO Publications and Documents - Circulars - Maritime Safety Committee - MSC/Circular.1102 – Interpretations of the 2000 HSC Code and SOLAS Chapter X – (15 September 2003) - Annex 1 - Interpretations of Provisions of the 2000 HSC Code - Section 7.7.3.2.7 Warning of release of extinguishing medium to ro-ro spaces and other spaces where personnel can enter

Section 7.7.3.2.7 Warning of release of extinguishing medium to ro-ro spaces and other spaces where personnel can enter

  1 Ro-ro spaces and other spaces where personnel can be expected to enter and where the access is facilitated by doors or hatches should be provided with an automatic warning for the release of the extinguishing medium.

  2 The pre-discharge alarm should be automatically activated (e.g. by opening of the release cabinet door).

  3 Reference is made to the Code on Alarms and Indicators, 1995 (resolution A.830(19)).


Copyright 2022 Clasifications Register Group Limited, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasifications Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasifications Register'. Clasifications Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasifications Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.