5.1 General 
                     
                     
                     
                     
                     5.1.1
                        
                     
                     
                     
                     
                     The use of excessive force is to be avoided during the assembly of individual
                        structural components or during the erection of sections. Major distortions of
                        individual structural components are to be corrected before further assembly. After
                        completion of welding, straightening and aligning are to be carried out in such a manner
                        that the material properties are not influenced significantly. In case of doubt, the
                        Society may require a procedure test or a working test to be carried out. 
                     
                     
                     
                     
                     5.1.2 
                     
                     
                     
                     Structural members are to be aligned following the provisions of IACS
                        Recommendation No. 47, Tables 7 or according to the requirements of a recognised
                        fabrication standard that has been accepted by the Society. In the case of critical
                        components, control drillings are to be made where necessary, which are then to be
                        welded up again on completion.