8.4.1 Where foundations have skirts, dowels or other seabed penetrating
elements which transfer load to the seabed, the effect of these components is to be
taken into account when determining the efficiency of, and loads in, the foundations
for bearing capacity and sliding resistance. These items are to be designed as
structural members.
8.4.2 The resistance of skirts, dowels and other seabed penetrating elements
to penetration of the seabed during installation of the foundation and their effect,
if any, on water flow beneath the foundation during installation is to be taken into
account in the design calculations.
8.4.3 The penetration resistance of elements such as skirts and dowels is to
be based on conservative (upper bound) estimates of soil strength. Also, by
considering more typical penetration resistances, account may be taken of the
foundation in formulating possible eccentric ballasting requirements.
8.4.4 The gravity base anchor installation should ensure that any skirts or
other seabed penetrating elements penetrate as required by the design.
8.4.5 Provision is to be made for the relief of water pressure generated
within the skirts during installation of the structure.