Chapter 2.3 – Class 3 Flammable liquids
Clasification Society 2024 - Version 9.40
Statutory Documents - IMO Publications and Documents - Resolutions - Maritime Safety Committee - Resolution MSC.294(87) – Adoption of Amendments to the International Maritime Dangerous Goods (IMDG) Code – (Adopted on 21 May 2010) - Annex – Amendments to the International Maritime Dangerous Goods (IMDG) Code - Part 2 – Classification - Chapter 2.3 – Class 3 Flammable liquids

Chapter 2.3 – Class 3 Flammable liquids

  2.3.4 Add a new section 2.3.4 with the following:

  • “2.3.4 Determination of initial boiling point

    The following methods for determining the initial boiling point of flammable liquids may be used:

    International standards:
      ISO 3924
      ISO 4626
      ISO 3405
       
    National standards:
    American Society for Testing Materials International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, Pennsylvania, USA 19428-2959:
      ASTM D86-07a, Standard Test Method for Distillation of Petroleum Products at Atmospheric Pressure
      ASTM D1078-05, Standard Test Method for Distillation Range of Volatile Organic Liquids
    Further acceptable methods:
      Method A.2 as described in Part A of the Annex to Commission Regulation (EC) No.440/2008footnote.".

2.3.3 Determination of flash point

  2.3.3.6 The existing section is replaced by the following:

  • "2.3.3.6 Determination of flash point

    The following methods for determining the flash point of flammable liquids may be used:

International standards:
  ISO 1516
  ISO 1523
  ISO 2719
  ISO 13736
  ISO 3679
  ISO 3680
   
National standards:
American Society for Testing Materials International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, Pennsylvania, USA 19428-2959:
  ASTM D3828-07a, Standard Test Methods for Flash Point by Small Scale Closed Cup Tester
  ASTM D56-05, Standard Test Method for Flash Point by Tag Closed Cup Tester
  ASTM D3278-96(2004)e, Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus
  ASTM D93-08, Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester.
Association française de normalisation, AFNOR, 11, rue de Pressensé, 93571 La Plaine Saint-Denis Cedex:
  French Standard NF M 07 – 019
  French Standards NF M 07 – 011/NF T 30 – 050/NF T 66 – 009
  French Standard NF M 07 – 036
Deutsches Institut für Normung, Burggrafenstr. 6, D-10787 Berlin:
  Standard DIN 51755 (flash points below 65°C)
State Committee of the Council of Ministers for Standardization, 113813, GSP, Moscow, M-49 Leninsky Prospect, 9:
  GOST 12.1.044-84".

Copyright 2022 Clasifications Register Group Limited, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasifications Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasifications Register'. Clasifications Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasifications Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.