5.9.1 The Administration should ensure that the
sewage treatment plant can operate under conditions of tilt consistent
with internationally acceptable shipboard practice up to 22.5º
in any plane from the normal operating position.
5.9.2 Tests for certification should be carried
out over the range of salinity and the range of temperatures for ambient
air and flush water specified by the manufacturer, and the Administration
should be satisfied that such specifications are adequate for the
conditions under which the equipment must operate.
5.9.3 Control and sensor components should be
subjected to environmental testing to verify their suitability for
marine use. The Test Specifications section in part 3 of the annex
to the Revised Guidelines and Specifications for Pollution Prevention
Equipment for Machinery Space Bilges of Ships (resolution MEPC.107(49)) provides guidance in this respect.
5.9.4 Any limitation on the conditions of operation
should be recorded on the certificate.
5.9.5 The Administration should also consider
requiring the manufacturer to include in the operating and maintenance
manuals, a list of chemicals and materials suitable for use in the
operation of the sewage treatment plant.