Clasification Society Rulefinder 2020 - Version 9.33 - Fix
Statutory Documents - MCA Publications - LY3 - The Large Commercial Yacht Code - 14A Structural Fire Protection - Vessels of Less than 500GT - 14A.5 Arrangements for gaseous fuel for domestic purposes |
||
![]() 14A.5 Arrangements for gaseous fuel for domestic purposes14A.5.1 Where gaseous fuel is used for domestic purposes, the arrangements for the storage, distribution and utilisation of the fuel is to be such that, having regard to the hazards of fire and explosion which the use of such fuel may entail, the safety of the yacht and the persons onboard is preserved. The installation is to be in accordance with recognised National or International Standards. Hydrocarbon gas detectors and carbon monoxide detectors should be provided. 14A.5.2 Gas cylinders, regulators and safety devices should be stowed on the open deck (where leakage will not accumulate) or in a compartment that is vapour-tight to the vessels interior, and fitted with a vent and drain, so that any gas which may leak can disperse overboard. 14A.5.3 An open flame gas appliance provided for cooking, heating or any other purpose should comply with the requirements of EC Directive 90/396/EEC or equivalent. The installation of an open flame gas appliance should comply with the appropriate provisions of Annex 3. |
||
|
||
|