10 Documentation and information for each type
of lifeboat release and retrieval system should be submitted to the
Administration, or recognized organization acting on its behalf, in
order that an assessment can be carried out to determine compliance
with paragraphs 4.4.7.6.4 to 4.4.7.6.6 of the LSA Code. The manufacturer
should submit the approval certificate, along with all associated
supporting design calculations, plans and testing documentation to
the Administration or recognized organization acting on its behalf.
The design information should include the specification and the installation
instructions for the complete operating system as well as all safety
instructions regarding the operating system and any interlocks provided.
Any submission for testing of a lifeboat release and retrieval system
that cannot be supported with the above-mentioned information should
not be eligible for testing against the requirements of the LSA Code.
11 If the outcome of the design review is non-compliance
with the applicable paragraphs of the LSA Code, the lifeboat release
and retrieval system should be replaced or modified to be made compliant.