The calibration of all measuring instruments shall comply
with the requirements as set out in tables 1 and 2 and shall be traceable to national or
international standards.
Table 1 Engine-related
permissible deviations for measurements on a test bed
No.
|
Item
|
Permissible deviation
(± % values based on
engines' maximum values)
|
Calibration intervals
(months)
|
1
|
Engine
speed
|
2%
|
3
|
2
|
Torque
|
2%
|
3
|
3
|
Power
|
2%
|
not
applicable
|
4
|
Fuel
consumption
|
2%
|
6
|
5
|
Air
consumption
|
2%
|
6
|
6
|
Exhaust
gas flow
|
4%
|
5
|
Table 2 Permissible deviations
of essential measured parameters for measurements on a test bed
No.
|
Item
|
Permissible deviation
(± absolute values)
|
Calibration intervals
(months)
|
1
|
Coolant
temperature
|
2
K
|
3
|
2
|
Lubricant temperature
|
2
K
|
3
|
3
|
Exhaust
gas pressure
|
5% of
maximum
|
3
|
4
|
Inlet
manifold depressions
|
5% of
maximum
|
3
|
5
|
Exhaust
gas temperature
|
15
K
|
3
|
6
|
Air
inlet temperature (combustion air)
|
2
K
|
3
|
7
|
Atmospheric pressure
|
0.5% of
reading
|
3
|
8
|
Intake
air humidity (relative)
|
3%
|
1
|
9
|
Fuel
temperature
|
2
K
|
3
|