17.10 Flame screens on vent outlets
Clasification Society 2024 - Version 9.40
Statutory Documents - IMO Publications and Documents - International Codes - 1983 IGC Code - International Code for the Construction and Equipment of Ships Carrying Liquefied Gases in Bulk - Chapter 17 Special Requirements - 17.10 Flame screens on vent outlets

17.10 Flame screens on vent outlets

 Cargo tank vent outlets should be provided with readily renewable and effective flame screens or safety heads of an approved type when carrying a cargo referenced to this section. Due attention should be paid in the design of flame screens and vent heads to the possibility of the blockage of these devices by the freezing of cargo vapour or by icing up in adverse weather conditions. Ordinary protection screens should be fitted after removal of the flame screens.


Copyright 2022 Clasifications Register Group Limited, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasifications Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasifications Register'. Clasifications Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasifications Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.