1 The conductivity of soluble salts is measured
in accordance with ISO 8502-6 and ISO 8502-9, and compared with the
conductivity of 50 mg/m2 NaCI. If the measured conductivity
is less then or equal to, then it is acceptable.
2 All soluble salts have a detrimental effect
on coatings to a greater or lesser degree. ISO 8502-9:1998 does not
provide the actual concentration of NaCI. The % NaCI in the total
soluble salts will vary from site to site. Minimum readings to be
taken should be one (1) reading per block/section/unit prior to applying.