1.1 Purpose 
                     
                     
                     
                     
                     1.1.1
                        
                     
                     
                     
                     
                     Design standard provides fatigue resistant detail design at an early stage in
                        the structural design process by giving consideration to the following aspects:
                        
                           -  Application of fatigue design principles. 
- Construction tolerances and other practical considerations. 
- In-service experience and fatigue performance.
1.1.2The design standard is to be applied to the design of ship structural details
                        in following steps: 
                        
                           - Highlighting potential critical areas within the ship structure. 
- Identification of the fatigue hot spot locations for each of the critical
                              structural details. 
                           
- Provision of a set of alternative improved configurations from which a suitable
                              solution can be selected. 
                           
- Requirements on geometrical configurations, scantlings, welding requirements and
                              construction tolerances. 
                           
- Post fabrication method of improving fatigue life, such as weld toe grinding.
                              
                           
1.2 Application 
                     
1.2.1
                        
                     
                     
                     
                     
                     The structural details described in this section are to be designed according
                        to the given design standard but alternative detail design configurations may be
                        accepted subject to demonstration of satisfactory fatigue performance. 
                     
                     
                     
                     
                     For the details given in Ch 9, Sec 2, Table 3, the fatigue assessment by very
                        fine mesh finite element analysis may be omitted if the detail is designed in accordance
                        with the design standard given in this section.