Sheer allowance for excess height of superstructure ( Regulation 38(7) and (12) ) (IACS interpretation LL.30)
Clasification Society 2023 - Version 9.38
Statutory Documents - IMO Publications and Documents - International Conventions - Load Lines, 1966/1988 - International Convention on Load Lines, 1966, as Amended by the Protocol of 1988 - Unified Interpretations of the Provisions of the International Convention on Load Lines, 1966 - Sheer allowance for excess height of superstructure (Regulation 38(7) and (12)) (IACS interpretation LL.30)

Sheer allowance for excess height of superstructure ( Regulation 38(7) and (12) ) (IACS interpretation LL.30)

 As regulation 38(7) and (12) does not refer to a raised quarter-deck, credit should be given for this type of superstructure only where the height of the raised quarter-deck is greater than the standard height of "other superstructures" as defined in regulation 33, and only for the amount by which the actual height of the raised quarter-deck exceeds that standard height.


Copyright 2022 Clasifications Register Group Limited, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasifications Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasifications Register'. Clasifications Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasifications Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.