1.1.1 A vessel shall not discharge unfiltered
effluent if the oil content of the effluent, without dilution, exceeds
15 ppm.
(Reference MARPOL 9 (2) (now regulation 15.6), 10(2)(b)) (now regulation 15.6)
1.1.2 A vessel may discharge effluent through
filtering equipment providing that oil content of the discharged effluent,
without dilution, does not exceed 15 ppm;
(Reference MARPOL 9(2) (now regulation
15.6), 16(3)(b)) (now regulation
14.4)
-
1.1.2.1 Vessels discharging effluent in special
areas (see paragraph 1.6) but excluding the Antarctica area shall
be fitted with:-
-
1.1.2.1.1 a monitoring device that will provide
an alarm should the discharge effluent exceed 15 ppm; and
-
1.1.2.1.2 a stopping device which will ensure
the discharge is automatically stopped should the discharge effluent
oil content exceed 15 ppm.
(Reference MARPOL 9(2)
(now regulation 15.6),
16(3)(b) (now regulation 14.4),
10(3)(b) (now regulation 15.3)
& Interpretation 3.4)