12 After a successful completion of the design
review, a performance test should be conducted by the manufacturer
for each type of lifeboat release and retrieval systems for compliance
with paragraphs 4.4.7.6.4 to 4.4.7.6.6 of the LSA Code, using the
test specified in appendix 1 to these Guidelines. The performance
test should be witnessed by the Administration or a recognized organization
acting on its behalf.
13 Should any part of the lifeboat release and
retrieval system fail at any stage during the test specified in paragraphs
1 to 4 of appendix 1, this type of lifeboat release and retrieval
system should be deemed to be non-compliant and reported as such.