7.10 Emergency source of electrical power
Clasification Society 2024 - Version 9.40
Statutory Documents - IMO Publications and Documents - International Codes - 2009 MODU Code - Code for the Construction and Equipment of Mobile Offshore Drilling Units, 2009 – Resolution A.1023(26) - Chapter 7 - Machinery and Electrical Installations for Self-Propelled Units - 7.10 Emergency source of electrical power

7.10 Emergency source of electrical power

 In addition to complying with section 5.4, the emergency source of power should provide:

  • .1 For a period of 18 hours, emergency lighting at the steering gear;

  • .2 For a period of 18 hours:

    • .2.1 navigational aids as required by SOLAS chapter V;

    • .2.2 intermittent operation of the daylight signalling lamp and the unit’s whistle;

    unless they have an independent supply from an accumulator battery suitably located for use in an emergency and sufficient for the period of 18 hours;

  • .3 For the period of 30 min or a lesser period as permitted by SOLAS regulation II-1/29.14, the steering gear.


Copyright 2022 Clasifications Register Group Limited, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasifications Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasifications Register'. Clasifications Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasifications Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.