10.1 IEC 92-504 requires that electrical, electronic
and programmable equipment intended for control, monitoring, alarm,
and protection systems in ships should operate satisfactorily within
the following conditions:
General shipboard conditions.
- displacement amplitude ± 1.5 mm in the frequency range
2 Hz - 13 Hz.
- acceleration amplitude ± 10 m/s2 in the frequency
range 13 Hz -100 Hz.
At special locations, for example directly on all engines, diesel
engine exhaust systems, diesel generator sets, compressors, and in
steering gear rooms:
- displacement amplitude ± 1.5 mm in the frequency range
2 Hz - 28 Hz.
- acceleration amplitude ± 50 m/s2 in the frequency
range 28 Hz -100 Hz.