5.9.6.1 After the procedures in 5.9.1 to 5.9.5 have been completed, the test sequence shall
be started. The engine shall be operated in each mode in accordance
with the appropriate test cycles defined in 3.2.
5.9.6.2 During each mode of the test cycle after
the initial transition period, the specified speed shall be held to
within ± 1% of rated speed or ± 3 min-1,
whichever is greater, except for low idle, which shall be within the
tolerances declared by the manufacturer. The specific torque shall
be held so that the average, over the period during which the measurements
are to be taken, is within 2% of the maximum torque at the test speed.