4.11.1 Each seawater inlet and discharge in spaces
below the assigned load line should be provided with a valve operable
from an accessible position outside the space on:
4.11.2 The control systems and indicators provided
in paragraph 3.6.5.1 should be operable in both normal conditions
and in the event of main power failure. Where stored energy is provided
for this purpose, its capacity should be to the satisfaction of the
Administration.
4.11.3 Non-metallic expansion joints in piping
systems, if located in a system which penetrates the unit’s
side and both the penetration and the non-metallic expansion joint
are located below the deepest load waterline, should be inspected
as part of the dry-dock survey in section 1.6 and replaced as necessary,
or at an interval recommended by the manufacturer.