Age ≤ 5 years
|
5 < Age ≤ 10 years
|
10 < Age ≤ 15 years
|
Age > 15 years
|
Renewal Survey No. 1
|
Renewal Survey No. 2
|
Renewal Survey No. 3
|
Renewal Survey No. 4 and subsequent
|
(A) ONE WEB FRAME RING – in a ballast wing
tank, if any, or a cargo wing tank used primarily for water ballast
(B) ONE DECK TRANSVERSE – in a cargo oil tank
(D) ONE TRANSVERSE BULKHEAD – in a ballast tank
(D) ONE
TRANSVERSE BULKHEAD – in a cargo oil wing tank
(D) ONE
TRANSVERSE BULKHEAD – in a cargo oil centre tank
|
(A) ALL WEB FRAME RINGS – in a ballast
wing tank, if any, or a cargo wing tank used primarily for water ballast
(B) ONE DECK TRANSVERSE – in each of the remaining ballast
tanks, if any
(B) ONE DECK TRANSVERSE – in a cargo wing
tank
(B) ONE DECK TRANSVERSE – in two cargo centre
tanks
(C) BOTH TRANSVERSE BULKHEADS in a wing ballast
tank, if any, or a cargo wing tank used primarily for water ballast
(D) ONE TRANSVERSE BULKHEAD – in each remaining ballast tank
(D) ONE TRANSVERSE BULKHEAD – in a cargo oil wing tank
(D) ONE TRANSVERSE BULKHEAD – in two cargo oil centre
tanks
|
(A) ALL WEB FRAME RINGS – in all ballast
tanks
(A) ALL WEB FRAME RINGS – in a cargo wing tank
(A) A minimum of 30% of all web frame rings in each remaining
cargo wing tank (see note 1)
(C) ALL TRANSVERSE BULKHEADS
– in all cargo and ballast tanks
(E) A minimum of 30% of
deck and bottom transverses including adjacent structural members in each
cargo centre tank (see note 1)
(F) As considered
necessary by the Administration
|
As for renewal survey No.3
Additional transverses included as deemed necessary by the
Administration
|
|
|
|
|
Note
1:
|
The 30%
shall be rounded up to the next whole integer.
|
(A), (B),
(C), (D), (E) and (F) are areas which shall be subjected to close-up surveys
and thickness measurements (see appendix 3 to annex 10).
|
(A) Complete
transverse web frame ring including adjacent structural members
|
(B) Deck
transverse including adjacent deck structural members
|
(C)
Transverse bulkheads complete – including girder system and adjacent structural
members
|
(D)
Transverse bulkhead lower part – including girder system and adjacent
structural members
|
(E) Deck and
bottom transverse including adjacent structural members
|
(F)
Additional complete transverse web ring frame
|
|
|
|
|