For the purpose of these Standards, the following definitions
are applicable.
1.3.1 “Flame arrester" is a device to prevent
the passage of flame in accordance with a specified performance standard.
Its flame-arresting element is based on the principle of quenching.
1.3.2 “Flame screen" is a device utilizing
wire mesh to prevent the passage of unconfined flames, in accordance
with a specified performance standard.
1.3.3 “Flame speed" is the speed at which
a flame propagates along a pipe or other system.
1.3.4 “Flashback" is the transmission of
a flame through a device.
1.3.5 “High velocity vent" is a device to
prevent the passage of flame, consisting of a mechanical valve which
adjusts the openings available for flow in accordance with the pressure
at the inlet of the valve in such a way that the efflux velocity cannot
be less than 30 m/s.
1.3.6 “Pressure/vacuum valve"footnote is a device designed to maintain pressure
and vacuum in a closed container within preset limits.