11.1 Each portable fire extinguisher on a vessel
shall be of an approved type. The minimum number of portable fire
extinguishers required on a vessel shall be acceptable to the Administration,
and shall be not less than the minimum number required by
Table V.11
and other provisions
of this regulation.
Table V.11
Space protected
|
Minimum No.
required
|
Type extinguisher permitted
|
Class
|
Medium
|
Minimum size
|
Operating Station
|
1
|
B-I, C-I ........
|
CO2 ..............
|
1.8 kg (4 lb).
|
|
|
|
Dry Chemical ...
|
0.9 kg (2 lb)
|
Machinery Space
|
1
|
B-II, C-II located just outside
exit.
|
CO2 ..............
|
6.8 kg (15 lb)
|
|
|
|
|
|
Accommodation Spaces ..
|
1 for each 232.3
m2 (2,500 square feet) or part thereof).
|
A-II .............
|
Foam .............
|
9.5 l (2.5 gal)
|
|
|
Dry Chemical ....
|
4.5 kg (10 lb)
|
|
|
CO2
|
6.8 kg (15 lb)
|
|
|
|
|
|
Galley, Pantry, Concession
Stand
|
1
|
A-II, B-II........
|
Foam .............
|
9.5 l (2.5 gal)
|
|
|
|
Dry Chemical ....
|
4.5 kg (10 lb)
|
11.2 The installation and location of the portable