A lifeboat which has a water spray flre-protection system
shall comply with the following:
-
.1 water for the system shall be drawn from the
sea by a self-priming motor pump. It shall be possible to turn "on"
and turn "off" the flow or water over the exterior of the lifeboat;
-
.2 the seawater intake shall be so arranged as
to prevent the intake of flammable liquids from the sea surface; and
-
.3 the system shall be arranged for flushing with
fresh water and allowing complete drainage.