5.9.9 Re-checking the analysers
Clasification Society 2024 - Version 9.40
Statutory Documents - IMO Publications and Documents - International Codes - NOx Technical Code (2008) - Technical Code on Control of Emission of Nitrogen Oxides from Marine Diesel Engines - Chapter 5 - Procedures for NOx emission measurements on a test bed - 5.9 Test run - 5.9.9 Re-checking the analysers

5.9.9 Re-checking the analysers

  5.9.9.1 After the emission test, the zero and span responses of the analysers shall be re-checked using a zero gas and the same span gas as used prior to the measurements. The test shall be considered acceptable if:

  • .1 the difference between the responses to the zero gas before and after the test is less than 2% of the initial span gas concentration; and

  • .2 the difference between the responses to the span gas before and after the test is less than 2% of the initial span gas concentration.

  5.9.9.2 Zero and span drift correction shall not be applied to the analyser responses recorded in accordance with 5.9.7.


Copyright 2022 Clasifications Register Group Limited, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasifications Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasifications Register'. Clasifications Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasifications Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.