5.9.9.1 After the emission test, the zero and
span responses of the analysers shall be re-checked using a zero gas
and the same span gas as used prior to the measurements. The test
shall be considered acceptable if:
-
.1 the difference between the responses to the
zero gas before and after the test is less than 2% of the initial
span gas concentration; and
-
.2 the difference between the responses to the
span gas before and after the test is less than 2% of the initial
span gas concentration.
5.9.9.2 Zero and span drift correction shall not
be applied to the analyser responses recorded in accordance with 5.9.7.