LR III.4.1
The class notation APBU (maximum duration in days) will be assigned when
the notation (design) vapour pressure allows the cargo to warm up during the
duration of the voyage with the purpose of containing the boil-off gas (BOG) within
the cargo tanks during normal operations. The insulation and the allowable maximum
vapour pressure will be considered when determining the maximum voyage length at the
ambient design temperatures stated in Ch 7,7.2. The given duration of voyage is to
have a suitable margin, for the operating time and temperatures involved, which is
to be acceptable to the Administration, see Ch 7,7.5. The design vapour
pressure will be no greater than permitted by the definitions of containment systems
in Ch 4, 4.1.2. Compliance with paragraphs LR 7.2-01, LR 15.1-03, and LR 18.1-02 is
required.