3.4.1 Any cargo control room
should be above the weather deck and may be located in the cargo area.
The cargo control room may be located within the accommodation spaces,
service spaces or control stations provided the following conditions
are complied with:
3.4.2 If the cargo control
room is designed to be a gas-safe space, instrumentation should, as
far as possible, be by indirect reading systems and should in any
case be designed to prevent any escape of gas into the atmosphere
of that space. Location of the gas detector within the cargo control
room will not violate the gas-safe space if installed in accordance
with 13.6.5.
3.4.3 If the cargo control
room for ships carrying flammable cargoes is a gas-dangerous space,
sources of ignition should be excluded. Consideration should be paid
to the safety characteristics of any electrical installations.