Clasification Society Rulefinder 2020 - Version 9.33 - Fix
Statutory Documents - MCA Publications - LY3 - The Large Commercial Yacht Code - 14A Structural Fire Protection - Vessels of Less than 500GT - 14A.2 Structure - 14A.2.3 Materials |
||
![]() 14A.2.3 Materials14A.2.3.1 Except in refrigerated compartments of service spaces, all insulation (e.g. thermal and acoustic) is to be of not readily-ignitable materials. 14A.2.3.2 Pipes penetrating 'A' or 'B' Class divisions are to be of approved materials having regard to the temperature such divisions are required to withstand. 14A.2.3.3 Pipes conveying oil or other combustible liquids through accommodation and service spaces are to be of approved materials having regard to the fire risk. 14A.2.3.4 Materials readily rendered ineffective by heat are not to be used for overboard scuppers, sanitary discharges, and other outlets which are close to the waterline and where the failure of the material in the event of fire would give rise to danger of flooding. Due regard should be paid to the IMO Fire Test Procedures Code. 14A.2.3.5 Vapour barriers and adhesives used in conjunction with insulation, as well as insulation of pipe fittings for cold service system need not be non-combustible, but they are to be kept to the minimum quantity practicable and their exposed surfaces are to have low flame spread characteristics. 14A.2.3.6 Upholstery composites (fabric in association with any backing or padding material) used throughout the vessel including open decks should be approved in accordance with the IMO FTP Code, Annex 1, Part 8, or equivalent. This does not apply to spaces fitted with sprinklers or equivalent fixed fire extinguishing systems. 14A.2.3.7 Organic foams used in upholstered furniture and mattresses should be of the combustion modified type. 14A.2.3.8 Suspended textile materials such as curtains or drapes should be approved in accordance with the IMO FTP Code, Annex 1, Part 7, or equivalent. This does not apply to spaces fitted with sprinklers or equivalent fixed fire extinguishing systems. |
||
|
||
|