Multilateral approval Delete the last sentence
("The term … "through or into" specifically excludes … that
country").
Pressure receptacle Before "and bundles" insert
", metal hydride storage systems".
Repaired IBC In the second sentence, "manufacturer's
specification" is replaced with "design type from the same manufacturer".
Tank At the end of the sentence, "substances
of class 2" is replaced with "gases as defined in 2.2.1.1".
Cargo transport unit is replaced by the following:
-
"Cargo transport unit means a road transport
tank or freight vehicle, a railway transport tank or freight wagon,
a multimodal freight container or portable tank, or a MEGC;".
Closed cargo transport unit is replaced by
the following:
-
"Closed cargo transport unit, with the exception of class
1, means a cargo transport unit which totally encloses the contents
by permanent structures with complete and rigid surfaces. Cargo transport
units with fabric sides or tops are not considered closed cargo transport
units; for definition of class 1 cargo transport unit see
7.1.7.1.1."
GHS In the first sentence "second" is replaced
with "third" and the reference "Rev.2" is replaced with "Rev.3".
Liquids After "(ADR)" insert ", as amended"
and the footnote is deleted.
Tank Insert a hyphen between "tank" and "wagon"
and between "tank" and "vehicle".
The following new definitions are inserted in alphabetical
order:
-
"Fuel cell means an electrochemical device
that converts the chemical energy of a fuel to electrical energy,
heat and reaction products.
-
Fuel cell engine means a device used to power
equipment and which consists of a fuel cell and its fuel supply, whether
integrated with or separate from the fuel cell, and includes all appurtenances
necessary to fulfil its function.
-
Manual of test and criteria means the fifth
revised edition of the United Nations publication entitled "Recommendations
on the Transport of Dangerous Goods, Manual of Tests and Criteria"
(ST/SG/AC.10/11/Rev.5).
-
Metal hydride storage system means a single
complete hydrogen storage system, including a receptacle, metal hydride,
pressure relief device, shut-off valve, service equipment and internal
components used for the transport of hydrogen only.
-
Open cryogenic receptacle means a transportable
thermally insulated receptacle for refrigerated liquefied gases maintained
at atmospheric pressure by continuous venting of the refrigerated
liquefied gas.
-
Remanufactured large packaging means a metal
or rigid plastics large packaging that:
-
(a) Is produced as a UN type from a non-UN type;
or
-
(b) Is converted from one UN design type to another
UN design type. Remanufactured large packagings are subject to the
same provisions of this Code that apply to new large packagings of
the same type (see also design type definition in 6.6.5.1.2).
-
Reused large packaging means a large packaging
to be refilled which has been examined and found free of defects affecting
the ability to withstand the performance tests: the term includes
those which are refilled with the same or similar compatible contents
and are transported within distribution chains controlled by the consignor
of the product.
-
Through or into means through or into the countries
in which a consignment is transported but specifically excludes countries
"over" which a consignment is carried by air, provided that there
are no scheduled stops in those countries."