Statutory Documents - MCA Publications - LY3 - The Large Commercial Yacht Code - Annex 3 Open Flame Gas Installations - 2 Stowage of Gas Containers

2 Stowage of Gas Containers

  2.1 LPG cylinders, regulators and safety devices should be stowed on the open deck (where leakage will not accumulate) or in a compartment that is vapour-tight to the vessels interior, and fitted with a vent and drain, so that any gas which may leak can disperse overboard.

  2.2 The vent and drain should not be less than 19mm in diameter, run to the outside of the craft and terminate 75mm or more above the "at rest" waterline. Generally, the drain and locker ventilation should be 500mm or more from any opening to the interior.

  2.3 The cylinders and associated fittings should be positively secured against movement and protected from damage in any foreseeable event.

  2.4 Any electrical equipment located in cylinder lockers should be certified safe for use in the potential explosive atmosphere.


Copyright 2020 Clasification Society, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasification Society, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasification Society'. Clasification Society Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasification Society entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.