For symbols not defined in this section, refer to Ch 1, Sec 4.
αp : Correction factor for the panel aspect ratio to be taken as:
but not to be taken as greater than 1.0.
a : Length of plate panel, in mm, as defined in Ch 3, Sec 7, [2.1.1].
b : Breadth of plate panel, in mm, as defined in Ch 3, Sec 7, [2.1.1].
ℓbdg : Effective bending span, as defined in Ch 3, Sec 7, [1.1.2], in
m.
ℓslh : Effective sloshing length, in m, as defined in Ch 4, Sec 6,
[6.3.2].
bslh : Effective sloshing breadth, in m, as defined in Ch 4, Sec 6,
[6.4.2].
Iy-n50 : Net horizontal hull girder moment of inertia, at the
longitudinal position being considered, as defined in Ch 5, Sec 1, [1.5], in
m4.
Msw : Permissible hull girder hogging and sagging still water bending
moment for seagoing operation at the location being considered, in kNm, as defined in Ch
4, Sec 4, [2.2.2].
zn : Distance from the baseline to the horizontal neutral axis, as
defined in Ch 5, Sec 1, in m.
z : Vertical coordinate of the load calculation point or at the reference point
under consideration, in m.
σ
hg : Hull girder bending stress, in N/mm
2, calculated at
the load calculation point defined in Ch 3, Sec 7, [2.2] or in Ch 3, Sec 7, [3.2], as
the case may be: