5.9.7 Analyser response
Clasification Society 2024 - Version 9.40
Statutory Documents - IMO Publications and Documents - International Codes - NOx Technical Code (2008) - Technical Code on Control of Emission of Nitrogen Oxides from Marine Diesel Engines - Chapter 5 - Procedures for NOx emission measurements on a test bed - 5.9 Test run - 5.9.7 Analyser response

5.9.7 Analyser response

  5.9.7.1 When stabilized, the output of the analysers shall be recorded both during the test and during all zero and span response checks, using a data acquisition system or a strip chart recorder. The recording period shall not be less than 10 minutes when analysing exhaust gas or not less than 3 minutes for each zero and span response check. For data acquisition systems, a minimum sampling frequency of 3 per minute shall be used. Measured concentrations of CO, HC and NOx are to be recorded in terms of, or equivalent to, ppm to at least the nearest whole number. Measured concentrations of CO2 and O2 are to be recorded in terms of, or equivalent to, % to not fewer than two decimal places.


Copyright 2022 Clasifications Register Group Limited, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasifications Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasifications Register'. Clasifications Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasifications Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.