(1) Except as provided for in regulation 30(2), means shall be provided
to stop fans and close main openings to ventilation systems from outside
the spaces served.
(2) Means shall be provided for closing, from
a safe position, the annular spaces around funnels.
(3) Ventilation openings may be permitted in and
under the doors in corridor bulkheads except that such openings shall
not be permitted in and under stairway enclosure doors. The openings
shall be provided only in the lower half of a door. Where such opening
is in or under a door the total net area of any such opening or openings
shall not exceed 0.05 m2. When such opening is cut in a
door it shall be fitted with a grille made of non-combustible material.
(4) Ventilation ducts for machinery spaces of
category A or galleys shall not in general pass through accommodation
spaces, service spaces or control stations. Where the Administration
permits this arrangement, the ducts shall be constructed of steel
or equivalent material and arranged to preserve the integrity of the
divisions.
(5) Ventilation ducts of accommodation spaces,
service spaces or control stations shall not in general pass through
machinery spaces of category A or through galleys. Where the Administration
permits this arrangement the ducts shall be constructed of steel or
equivalent material and arranged to preserve the integrity of the
divisions.
(6) Store-rooms containing appreciable quantities
of highly flammable products shall be provided with ventilation arrangements
which are separate from other ventilation systems. Ventilation shall
be arranged at high and low levels and the inlets and outlets of ventilators
shall be positioned in safe areas. Suitable wire mesh guards to arrest
sparks shall be fitted over inlet and outlet ventilation openings.
(7) Ventilation systems serving machinery spaces
shall be independent of systems serving other spaces.
(8) Where trunks or ducts serve spaces on both
sides of "A" class bulkheads or decks, dampers shall be fitted so
as to prevent the spread of fire and smoke between compartments. Manual
dampers shall be operable from both sides of the bulkhead or the deck.
Where the trunks or ducts with a free cross-sectional area exceeding
0.02 m2 pass through "A" class bulkheads or decks, automatic
self-closing dampers shall be fitted. Trunks serving compartments
situated only on one side of such bulkheads shall comply with regulation 9(1)(b).