For the purpose of steel renewal, sand blasting and coating,
four zones A, B, C and D are defined, as shown in figure 1.
Representative thickness measurements shall be taken for each
zone and shall be assessed against the criteria in 2.1.
In
case of integral brackets, when the criteria in 2.1 are not satisfied
for zone A or B, steel renewal, sand blasting and coating, as applicable,
shall be done for both zones A and B.
In case of separate
brackets, when the criteria in 2.1 are not satisfied for zone A or
B, steel renewal, sand blasting and coating shall be done for each
one of these zones, as applicable.
When steel renewal
is required for zone C according to 2.1, it shall be done for both
zones B and C. When sand blasting and coating is required for zone
C according to 2.1, it shall be done for zones B, C and D.
When
steel renewal is required for zone D according to 2.1, it needs only
to be done for this zone. When sand blasting and coating is required
for zone D according to 2.1, it shall be done for both zones C and
D.
Special consideration may be given to zones previously
renewed or re-coated, if found in "as new" condition (i.e., without
breakdown or rusting) by the Administration or a classification society
which is recognized by the Administration in accordance with the provisions
of SOLAS regulation XI-1/1.
When adopted, on the basis of the renewal thickness criteria
in 2.1, in general coating shall be applied in compliance with the
requirements of the organization, as applicable.
Where,
according to the requirements in 2.1, a limited number of side frames
and brackets are shown to require coating over part of their length,
the following criteria apply:
In all cases, all the surfaces to be coated shall be sand blasted
prior to coating application.