6.3 Erection of materials
Clasification Society 2024 - Version 9.40
Statutory Documents - IMO Publications and Documents - International Codes - Noise Levels - Code on Noise Levels on Board Ships – Resolution A.468(XII) - Annex - Code on Noise Levels on Board Ship - Chapter 6 - Acoustic Insulation Between Accommodation Spaces - 6.3 Erection of materials

6.3 Erection of materials

  6.3.1 Care should be taken in the erection of materials and in the construction of accommodation spaces. During sea trial testing, if the erection of materials is in doubt then measurements should be taken on board ships for a representative selection of each type of partition, floors, doors as requested in paragraph 6.2.1 and to the satisfaction of the Administration.

  6.3.2 The apparent weighted sound reduction index R'w should comply with the requirements of the paragraph 6.2.1 with tolerance of up to 3 dB.

Note Field measurements should be performed according to ISO 140-4:1998footnote. When the area of the materials tested is <10 m2, a minimum value of 10 m2 should be considered for the calculation of the R'w index.


Copyright 2022 Clasifications Register Group Limited, International Maritime Organization, International Labour Organization or Maritime and Coastguard Agency. All rights reserved. Clasifications Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as 'Clasifications Register'. Clasifications Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Clasifications Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.