2.2.1
Table 2 lists
the ambient condition parameters that should be measured, or calculated,
and recorded at each mode point during on-board NOx monitoring.
Ambient Condition
Parameters
Symbol
|
Parameter
|
Dimension
|
Ha
|
absolute humidity (mass of engine
intake air water content related to mass of dry air)
|
g/kg
|
pB
|
total barometric pressure (in ISO
3046-1, 1995: px=Px=site ambient total pressure)
|
kPa
|
Ta
|
temperature at air inlet (in ISO
3046-1, 1995: Tx=TTx=site ambient thermodynamic air
temperature)
|
K
|